Installation, Operation & Maintenance
Instructions
Please leave this instruction booklet with the owner as
it contains important guarantee, maintenance and safety
information
Read this manual carefully before commencing installation.
This manual covers the following products:
CE compliant product
CHM160-30 B
Pt. No. 46607
CHM160-40 B
Pt. No. 46608
CHM160-50 B
Pt. No. 46609
CHM160-60 B
Pt. No. 46610
FOR POSITIVE OR NEGATIVE HEAD APPLICATIONS
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Instructions

Installation, Operation & Maintenance InstructionsPlease leave this instruction booklet with the owner as it contains important guarantee, mainten

Página 2 - APPLICATION

- 10 -3 ELECTRICAL INSTALLATION / EARTHING3.11 Regulations: The electrical installation must be carried out in accordance with the current na

Página 3 - Description Qty

- 11 -3.23 Supply Cord Replacement:The supply cord and internal wiring within the terminal box are routed and secured to ensure compliance with the e

Página 4 - PRE-INSTALLATION ASSEMBLY

- 12 -4.14 Starting: a) Ensure all outlets are closed, turn power supply ‘on’ - pump will start, pressurise the system then stop. b) Open

Página 5

- 13 -5 MAINTENANCE5.11 Turn off water supplies to the pump and release pressure by opening water outlets before attempting maintenance.5.12

Página 6 - 2 LOCATION - GENERAL

- 14 -Cont ...6 TECHNICAL SPECIFICATIONStuart Turner reserve the right to amend the specification in line with its policy of continuous development of

Página 7 - water cylinder

- 15 -7 TROUBLE SHOOTING GUIDESymptoms Probable Cause Recommended ActionPump will not start. Electrical supply. Check power supply.Check fuse (see fu

Página 8 - Hot water

- 16 -Cont ...7.11 Dry Run Protection: This pump is fitted with a safety control circuit, which will detect the following fault condition:  Dry r

Página 9

- 17 -Cont ... Briefly reconnect the mains power supply to the pump – the indicator light should illuminate if the pump has been correctly wired

Página 10 - Diagram of

- 18 -8 YOUR 1 YEAR GUARANTEEStuart Pumps are guaranteed by Stuart Turner Limited to be free from defects in materials or workmanship and the guarant

Página 11

- 19 -NOTES

Página 12

- 2 -Cont ...PRODUCT DESCRIPTIONElectric motor driven centrifugal pump complete with an automatic control system, consisting of flow switch, pressure

Página 13 - 5 MAINTENANCE

Stuart Turner Ltd, Henley-on-Thames, Oxfordshire RG9 2AD ENGLAND Tel: +44 (0) 1491 572655, Fax: +44 (0) 1491 573704email: pumps@stuart-turn

Página 14 - 6 TECHNICAL SPECIFICATION

- 3 -Cont ...CHECKLISTYour product may vary slightly from the picture above.ItemDescription QtyItemDescription QtyPump 1 Pressure vessel 1ABA BFig. 1I

Página 15 - 7 TROUBLE SHOOTING GUIDE

- 4 -Cont ...Fig. 2Grub Screws(3 off)Outlet Tower can be swivelled at this joint line after loosening the 3 equi-spaced grub screwsPRE-INSTALLATION AS

Página 16

- 5 -Cont ...1 READ BEFORE COMMENCING PUMP INSTALLATIONA. Water storage capacity.1.11 The hot and cold water storage capacity must be sufficient to

Página 17 - Cont

- 6 -Cont ...2 LOCATION - GENERAL2.11 Access: For emergencies and maintenance the pump must be easily accessible.2.12 Protection: The pump must

Página 18 - 8 YOUR 1 YEAR GUARANTEE

- 7 -Cont ...2 LOCATION - COLD WATER INSTALLATION2.26 The cold water supply: The supply must be AIR FREE and have a DEDICATED CONNECTION to

Página 19

- 8 -Cont ...2.27 Hot water cylinder or storage tank: When a hot water cylinder or storage tank is used, ensure the pipework size from the cold

Página 20 - Business Development Director

- 9 -Cont ...2.30 Non-Preferred Pump Location: The pump must be located with at least 1 metre flooded suction at all times. If it is not possibl