Installation, Operation & Maintenance InstructionsPlease leave this instruction booklet with the owner as it contains important guarantee, mainten
- 10 -3 ELECTRICAL INSTALLATION / EARTHING3.11 Regulations: The electrical installation must be carried out in accordance with the current na
- 11 -3.23 Supply Cord Replacement:The supply cord and internal wiring within the terminal box are routed and secured to ensure compliance with the e
- 12 -4.14 Starting: a) Ensure all outlets are closed, turn power supply ‘on’ - pump will start, pressurise the system then stop. b) Open
- 13 -5 MAINTENANCE5.11 Turn off water supplies to the pump and release pressure by opening water outlets before attempting maintenance.5.12
- 14 -Cont ...6 TECHNICAL SPECIFICATIONStuart Turner reserve the right to amend the specification in line with its policy of continuous development of
- 15 -7 TROUBLE SHOOTING GUIDESymptoms Probable Cause Recommended ActionPump will not start. Electrical supply. Check power supply.Check fuse (see fu
- 16 -Cont ...7.11 Dry Run Protection: This pump is fitted with a safety control circuit, which will detect the following fault condition: Dry r
- 17 -Cont ... Briefly reconnect the mains power supply to the pump – the indicator light should illuminate if the pump has been correctly wired
- 18 -8 YOUR 1 YEAR GUARANTEEStuart Pumps are guaranteed by Stuart Turner Limited to be free from defects in materials or workmanship and the guarant
- 19 -NOTES
- 2 -Cont ...PRODUCT DESCRIPTIONElectric motor driven centrifugal pump complete with an automatic control system, consisting of flow switch, pressure
Stuart Turner Ltd, Henley-on-Thames, Oxfordshire RG9 2AD ENGLAND Tel: +44 (0) 1491 572655, Fax: +44 (0) 1491 573704email: pumps@stuart-turn
- 3 -Cont ...CHECKLISTYour product may vary slightly from the picture above.ItemDescription QtyItemDescription QtyPump 1 Pressure vessel 1ABA BFig. 1I
- 4 -Cont ...Fig. 2Grub Screws(3 off)Outlet Tower can be swivelled at this joint line after loosening the 3 equi-spaced grub screwsPRE-INSTALLATION AS
- 5 -Cont ...1 READ BEFORE COMMENCING PUMP INSTALLATIONA. Water storage capacity.1.11 The hot and cold water storage capacity must be sufficient to
- 6 -Cont ...2 LOCATION - GENERAL2.11 Access: For emergencies and maintenance the pump must be easily accessible.2.12 Protection: The pump must
- 7 -Cont ...2 LOCATION - COLD WATER INSTALLATION2.26 The cold water supply: The supply must be AIR FREE and have a DEDICATED CONNECTION to
- 8 -Cont ...2.27 Hot water cylinder or storage tank: When a hot water cylinder or storage tank is used, ensure the pipework size from the cold
- 9 -Cont ...2.30 Non-Preferred Pump Location: The pump must be located with at least 1 metre flooded suction at all times. If it is not possibl