Installation, Operation & Maintenance
Instructions
Please leave this instruction booklet with the owner as
it contains important guarantee, maintenance and safety
information
Read this manual carefully before commencing installation.
This manual covers the following products:
TP50 - 1.5 bar Twin
Pt. No. 49045
TP55 - 2.0 bar Single
Pt. No. 49047
TP75 - 2.0 bar Twin
Pt. No. 49046
*1 year as standard extended to 2 years with a Techflange fitted
FOR POSITIVE HEAD APPLICATIONS ONLY
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Instructions

Installation, Operation & Maintenance InstructionsPlease leave this instruction booklet with the owner as it contains important guarantee, mainten

Página 2 - CONTENTS

- 10 -Cont ...3.13 Pumps supplied with flexible inlet and outlet hoses: Flexible pipes are supplied with this pump variant. The pump inlet and outl

Página 3 - Description Qty

- 11 -Cont ...3.14 Typical Low Level Installation: In certain installations it may be necessary to install a 90° bend on the inlet or outlet co

Página 4

- 12 -4 ELECTRICAL INSTALLATION / EARTHING4.11 Regulations: The electrical installation must be carried out in accordance with the current na

Página 5 - 2 LOCATION - GENERAL

- 13 -Cont ...4.21 Fuse: The following fuse size should be used with the appropriate pump:Model Fuse Size (AMPS)All Models 54.22 Internal WiringDo

Página 6 - Min. 0.5 m

- 14 -Cont ...5 COMMISSIONING5.11 System Flushing: This pump incorporates push-in connectors and plastic components that must not come into con

Página 7 - Fig. 6 (Single Pump)

- 15 -Cont ...6 MAINTENANCE  Do not remove the terminal box cover. No user serviceable parts inside.6.11 There are no user serviceable parts av

Página 8 - 3 PUMP CONNECTIONS

- 16 -Cont ...7 TECHNICAL SPECIFICATIONTechflow Products reserve the right to amend the specification in line with its policy of continuous developmen

Página 9

- 17 -Cont ...8 TROUBLE SHOOTING GUIDE8.11 Environment Protection: Your appliance contains valuable materials which can be recovered or recycled

Página 10 - Fig. 10

- 18 -Cont ...9 THE TECHFLOW PRODUCTS GUARANTEECongratulations on purchasing a Techflow Products pump. We are confident this pump will provide many y

Página 11 - Fig. 11

- 19 -In the event of a claim please telephone ‘Techflow Technical Helpline’ or return the pump and flexible hoses with the accessories removed e.g p

Página 12 - Diagram of

- 2 -PRODUCT DESCRIPTIONElectric motor driven twin ended peripheral pump complete with an automatic control system, consisting of flow switch and elec

Página 13 - Cont

Techfl ow Products, Service Department, Greys Road, Henley-on-Thames, Oxfordshire RG9 1RY ENGLAND Tel: +44 (0) 1444 258017, Fax: +44 (0) 1444

Página 14 - 5 COMMISSIONING

- 3 -CHECKLISTItemDescription QtyItemDescription QtyPump 1 Anti-vibration feet 4ISO Hose & washer 2 Inline strainers (not supplied) 2Plain Hose &a

Página 15 - 6 MAINTENANCE

- 4 -Cont ...1 READ BEFORE COMMENCING PUMP INSTALLATIONA. Water storage capacity.1.11 The hot and cold water storage capacity must be sufficient to

Página 16 - 7 TECHNICAL SPECIFICATION

- 5 -2 LOCATION - GENERAL2.11 Access: For emergencies and maintenance the pump must be easily accessible.2.12 Protection: The pump must be locat

Página 17 - 8 TROUBLE SHOOTING GUIDE

- 6 -Cont ...2 LOCATION - COLD WATER INSTALLATION2.26 The cold water supply: The supply must be AIR FREE and have a DEDICATED CONNECTION to

Página 18 - EXTEND YOUR PUMP GUARANTEE

- 7 -Cont ...2.31 Non-Preferred Pump Location: The pump must be located with at least 0.5 metre flooded suction at all times. If it is not pos

Página 19 - 01444 258017

- 8 -Cont ...3 PUMP CONNECTIONS  Do not use stainless steel, chrome or nickel plated pipe with the flexible hose push-in plumbing connections.

Página 20 - Business Development Director

- 9 -Cont ...3.12 Hose to pipework: 1. The hoses are fitted with plastic push-in connectors, which must only be connected with the follo