7 TECHNICAL SPECIFICATION
Techflow Products reserve the right to amend the specification in line with its policy of
continuous development of its products.
*Note: Max working pressure is the maximum pressure that can be applied to
the pump internal casing under any installation conditions.
**Note: In normal circumstances the temperature of stored water should never
exceed 65 °C. A stored water temperature of 60°C is considered
sufficient to meet all normal requirements and will minimise deposition of
scale in hard water areas.
Maximum permissible water temperature 65°C.
7.11 Noise: The equivalent continuous A-weighted sound pressure level at a distance
of 1 metre from the pump does not exceed 70 dB(A).
Model
TP50
1.5 bar Twin
TP75
2.0 bar Twin
TP55
2.0 bar Single
Electrical
Power supply
Volts/phase freqency
230/1/50 230/1/50 230/1/50
Enclosure IPX2 IPX2 IPX2
Type of motor Induction Induction Induction
Power consumption 385 Watts 420 Watts 215 Watts
Full load current 1.7 Amps 1.8 Amps 1.0 Amps
Rating
Int (S3) 30 mins on/30
mins off @ 9 l/min
(Both ends pumping)
Int (S3) 30 mins on/30
mins off @ 9 l/min
(Both ends pumping)
Int (S3) 30 mins on/30
mins off @ 9 l/min
Max. No Starts per hour 60 60 60
Mechanical
Max inlet head 10 metres 10 metres 10 metres
Max head (closed valve) 15 metres 19 metres 19 metres
Max working pressure* 300 kPa (3.0 bar) 300 kPa (3.0 bar) 300 kPa (3.0 bar)
Max ambient air temperature 40
o
C 40
o
C 40
o
C
Max water temperature** 65
o
C 65
o
C 65
o
C
Min water temperature 4
o
C4
o
C4
o
C
Pump
Dimensions
Length 231 mm 231 mm 208 mm
Width 132 mm 132 mm 132 mm
Height (excluding flexible hoses) 166 mm 166 mm 166 mm
Weight 4 Kg 4 Kg 3.2 Kg